Model |
AS-100C |
Light Source |
Infrared laser(905nm) |
Laser Safety Level |
Class I (GB7247.1-2012,Eye Safety) |
Laser Spot Divergence Angle |
2.0(H)×8.0(V)m rad |
Scanning Angle Range |
360° |
Scanning Frequency |
10Hz/20Hz |
Scanning Angle Resolution |
0.05°/0.1° |
Equipment Self-Inspection |
Content: light transmission cover dirty/blocked/high temperature/low temperature |
Working Voltage |
9V~30V DC |
Power Consumption |
5W@DC 24V |
Weight |
0.7kg |
Size |
110*96.5*71.5(mm) |
Static Electricity |
6KV(GB/T 17626.2~2006,Class 3) |
Electrical Fast Transient |
1KV(GB/T 17626.4~2008,Class 2) |
Electromagnetic Field Radiation Immunity |
GB/T 17626.3~2006,Class 2 |
Insulation Resistance |
1MΩ(GB16796~2009.5.4.4) |
Anti-surge |
GB/T17626.5-2008; Power interface: 1.2/50μs,2KV/1KA(Class 3); Ethernet interface: 10/700μs,1KV/25A(Class 2); I/O interface: 1.5/50μs,0.5KV/0.25KA(Class 1) |
Vibration Resistance |
GB/T 2423.10 |
Working Temperature |
-10ºC~+50ºC |
Ambient Illuminance |
≤80,000Lux |
Laser Spot Outlet Aperture |
10mm |
Detection Range |
0.2m~100m |
RSSI Detection Range |
3%~1000%(Reflctor) |
10% Reflectivity Range |
20m |
Environment |
It is resistant to sunlight,dirt and smoke penetration,and can be used under non-rainfall conditions |
Measuring Data |
Composite data (distance+RSSI) |
Measuring Error System Error (typical value) |
Distance measurement: 25mm(1m~20m)/40mm(20m~50m); RSSI measurement: 2%(1m~20m)/4%(20m~50m) |
measuring Statistical Error(1σ) |
Distance measurement: 10mm(1m~20m)/20mm(20m~50m); RSSI measurement: 1%(1m~20m)/2%(20m~50m) |
Ethernet |
Speed: 10/100 Mbps; Function: equipment configuration/measurement data output |
Input End |
Quantity: 3; Type: level input (vs. general input common ground "GND IN"); High level range: 9V - 30V DC; Low level range: 0V - 0.7V DC; Preset function: power saving and life extension control (IN2/IN3),effective level: high level |
Output End |
Quantity: 3; Type: PNP switch output (vs. positive end of power supply); Power-on status: off; Preset function: equipment ready (OUT),effective status: ON |
Indicator |
Quantity: 4; Definition: PWR: power indicator; LNK: Ethernet indicator; ERR: working fault indicator; HTR: normal measurement indicator |
Protection Degree |
IP65(GB4208~2008) |
Dielectric Strength |
0.5KV(GB16796~2009.5.4.3) |
Impact |
GB/T 2423.5 |
Single Impact |
15g,11ms |
Continuous Impact |
10g,16ms |
Frequency Range |
10Hz~150Hz |
Range |
5g |
Ambient Humidity |
93%,+40ºC,2h(GB/T 2423.3) |
Storing Temperature |
-30ºC~+70ºC |
Storing Temperature |
-30ºC~+70ºC |
Storing Temperature |
-30ºC~+70ºC |